V. Introduction to Each Processing Unit
VI. Manifold Process and Principles
The RSD/BFU60 brine filter is suitable for high-flow-rate filtration applications. Its large filtration area allows for the filtration of more impurities, and it is also suitable for applications requiring infrequent filter bag replacements. The unit has a compact structure, occupies little space, has a low profile, and facilitates filter bag replacement.
II、 Scope of applicationIt is widely applicable to water filtration treatment in fields such as petroleum, chemical, food and beverage, microelectronics, membrane industry, and metal processing.
III、 Features1. Employs a unique filtration design technology, providing excellent sealing and preventing side leakage;
2. The properly configured sealing rings ensure reliable system sealing, whether for single-bag or multi-bag filters;
3. Large flow rate per unit filtration area, low filtration resistance, and high filtration efficiency;
4. It has a wide range of applications and can be used for coarse filtration, medium filtration, or fine filtration.
IV、 Equipment process flowWater source → Booster pump → Stainless steel basket filter → Stainless steel precision filter → Water for use
V、 Brief introduction of each processing unit1. Stainless steel basket filter:
The device is equipped with two basket filters, which can be used simultaneously or individually for easy equipment maintenance. Basket filters are filtration devices that remove solid particles larger than 44 micrometers from liquids, protecting downstream equipment and providing coarse filtration for water sources. When fluid enters the filter cartridge, impurities are blocked, while clean filtrate is discharged from the filter outlet. When cleaning is required, simply remove the detachable filter cartridge, clean it, and reinstall it; operation and maintenance are extremely convenient.
2. Stainless steel precision (bag) filter
The device is equipped with two sets of 40-core precision filters, which can be used simultaneously or individually for easy equipment maintenance. The precision filters contain PP filter bags with a pore size of 1 micrometer to remove fine particles larger than 1 micrometer, meeting the requirements for production water.
The precision filter cover features a quick-release rocker arm design, facilitating rapid installation and removal of the filter bag for accurate and tight sealing.
Figure 1. Location of inlet and outlet
This system is a two-stage filtration process combining a basket filter and a bag filter. It includes two sets of primary basket filters and two sets of secondary bag filters, and can achieve four operating modes: "single primary filtration, primary parallel filtration, single set of series two-stage filtration, and double set of series two-stage filtration" to meet different water quality treatment needs.
wastewater inlet 废水入口 Primary filter 一级过滤器 basket strainer 篮式过滤器 Secondary filter 二级过滤器 bag filter 袋式过滤器 Flange butterfly valve 法兰式蝶阀
A7 First level filter entrance 一级过滤入口 A1 First level filter entrance First level filter outlet 一级过滤出口 A4 Secondary filter entrance 二级过滤入口 A3 Secondary filter outlet 二级过滤出口 A6 Clear water outlet 清水出口 A2 Secondary filter entrance 二级过滤入口 A5 Secondary filter outlet 二级过滤出口
1. Primary filtration used alone
(1) Applicable scenarios: scenarios where the wastewater flow rate is small, the wastewater impurity particles are large, and only coarse filtration is required.
(2) Operating steps:
1) Confirm that all valves are closed and check that the filter bags of the primary basket filter (corresponding units A1/A2) are installed in place.
2) Open valves A1 (or A2) and A4, and keep the other valves closed.
3) Slowly open the wastewater inlet valve and allow the system to operate stably after it is filled with the medium and there are no leaks.
4) The filtered water is discharged from the clean water outlet.
2. Primary filters are used in parallel.
(1) Applicable scenarios: Scenarios where the wastewater flow rate is large and a single primary filter cannot meet the treatment capacity.
(2) Operating steps:
Confirm that all valves are closed and check that the filter bags of the two sets of primary basket filters are installed in place.
Open valves A1, A2, and A4, and keep the rest of the valves closed.
Simultaneously and slowly open the wastewater inlet valve to evenly distribute the flow to the two sets of primary filters.
After filtration, the clean water is collected via A4 and discharged through the clean water outlet.
(3) Note: During operation, the pressure difference between the two sets of filters needs to be monitored. If the deviation is too large, the valve opening needs to be adjusted to balance the flow.
3. First and second level units are used in series.
(1) Applicable scenarios: scenarios where the wastewater flow rate is small and the wastewater impurities are complex, requiring deep treatment of "coarse filtration + fine filtration".
(2) Operating steps:
Confirm that all valves are closed, and check that the filter bags of the primary basket filter (corresponding to units A1/A2) and the secondary bag filter (corresponding to units A3/A5) are installed in place.
Open valves A1 (or A2), A3 (or A5), and A6 (or A7), and close valve A4.
Slowly open the wastewater inlet valve. After the medium is coarsely filtered by the primary basket filter, it enters the corresponding secondary bag filter for fine filtration.
After fine filtration, the clean water is transported from A6 (or A7) to the clean water outlet for discharge.
4. Primary and secondary dual-group series connection
(1) Applicable scenarios: scenarios with large wastewater flow and requiring deep treatment, maximizing the system's processing capacity.
(2) Operating steps:
Confirm that all valves are closed, and check that the filter bags of the two sets of primary basket filters and the two sets of secondary bag filters are installed in place.
Open valves A1, A2, A3, A5, A6, and A7, and close valve A4.
Slowly open the wastewater inlet valve. After the medium passes through the parallel coarse filter A1/A2, it enters the secondary bag filter corresponding to A3/A5 for fine filtration.
After fine filtration, the clean water is combined at A6/A7 and discharged from the clean water outlet.
(4) Note: During operation, the pressure difference of each filter needs to be monitored regularly. When the pressure difference exceeds 0.1MPa, the filter bag needs to be replaced.
VII、 Technical parameters1. Water inlet to the device
Inflow rate: 250–500 GPM (60–120 m³/h)
Inlet water pressure: 0.2-1.0 MPa
2. Water produced by the device
Water production rate: 250 GPM (57 m³/h)
3. Device Operation Status
Operating temperature of the device: 4-70℃
Operating water volume: 250~500GPM (60~120m³/h)
Operating pressure of the unit: 0.2-1.0 MPa
4. Technical parameters of each unit
4.1 Primary filter (basket filter)
Filtration accuracy: 44μm
Bag type available: Working pressure: 0.2-1.0 (MPa)
Nominal diameter of inlet and outlet: DN80
Filter material: 304
4.2 Secondary Filter (Bag Precision Filter)
Filtration accuracy: 1μm
Operating pressure: 0.2-1.0 (MPa)
Nominal diameter of inlet and outlet: DN80
Material: 304
5. External dimensions : 1900x1350x1800 mm
6. Weight : 1050 kg
VIII、 Instructions for use1. Before operating the system, check whether the inlet and outlet water pipes are installed correctly;
2. The frequency of equipment sewage discharge depends on the actual water quality during use;
3. There are two ways to determine when to replace the filter bag:
1) The replacement time is roughly determined based entirely on experience. (The standard practice)
2) Pressure gauges are installed on both the inlet and outlet pipes of the bag filter. The pressure difference displayed by the gauges determines when to replace the filter bags. Generally, the filter bags can withstand a pressure difference of about 1~3 kg/cm2. When the pressure difference reaches this range, the filter bags should be replaced promptly to avoid rupture and affecting the filtration effect. Do not sacrifice long-term benefits for short-term gains. (Special Requirements)
Ⅸ、 Parts replacement1. Replace the liquid inside the front drain equipment and open the top and bottom valves;
2. Loosen the eye bolts and nut on the top cover, and rotate the top cover counterclockwise or clockwise to the desired position;
3. Gently place the metal inner mesh into the bag filter, ensuring the mesh collar aligns with the inner flange of the bag filter;
4. Place the filter bag inside, ensuring the filter bag loop and the inner metal mesh collar fit together;
5. Use a locking wrench to rotate the pressure ring counterclockwise or clockwise to tighten the filter bag opening;
6. Rotate the top cover to align it with the lower flange of the bag filter, fasten the lifting eye bolts, and tighten the lifting eye nuts;
7. Close the valves installed at the top and bottom of the bag filter;
8. Please check that all connecting pipes are secure and that the working pressure is within the allowable range;
9. Open the output valve;
10. Slowly open the inlet valve to allow the liquid to flow in gently and fill the filter device. This prevents the liquid from suddenly impacting the filter bag and causing it to rupture. Then, observe for any leaks. If there are no leaks, you can begin filtration.
Material separation equipment manufacturer RSD recommended for youMud Hopper. You can learn moreMud HopperThe performance advantages, technical parameters, application fields and other information of, at the same time you can also understandDrilling solids control equipmentOther information or browsing products.